VIRDI AC 1000 User Guide 32
UNION COMMUNITY CO.,LTd.
3Fl. Hyundai Topics Bldg, 44-3 Bangi-dong, Songpa-gu, Seoul, Korea 138-050,
3.5.3.2. Door status monitor
◆ [ENT] Æ [3] Æ [3] Æ [ENT] ◆
< Door Monitor >
[0/1=NO/2=NC]:0
Default setting : ‘0’
- ‘0’: NW – no check
- ‘1’: NO – dead bolt type or auto door
(Lock monitoring is on when the door is locked)
- ‘2’: NC - strike type
(Lock monitoring is off when the door is locked)
‘0’ is for no check, ‘1’ is for dead bolt type or auto door; ‘2’ is for strike type.
When this is set to ‘1’ or ‘2’, the door condition connected to the terminal is
sent to the server periodically.
Once the setting is complete, Press [ENT] to move to the next setting.
3.5.3.3. Door open alarm settings
[ENT] ◆ Æ [3] Æ [3] Æ [ENT] Æ [ENT] ◆
< Door Open Alarm>
(00-30):00
Default setting: ‘00’
The terminal checks if the door has been open for more than setting time
(5sec~30sec) if so, it makes an alarm sound.
If this is set to ‘00’, there is no alarm sound.
This alarm helps the relevant person check what has caused the problem in a
timely manner and eliminate the problem.
For this function, the lock shall be able to monitor whether the door is open or
closed and its monitoring pin shall be connected to the terminal. The door
open check shall be set to ‘1’ or ‘2’ for this operation.
Once the setting is complete, press [ENT] to move to the upper setting.