AC-2100 User Guide 41
UNIONCOMMUNITY Co., Ltd. / 3F Hyundai Topix Bldg. 44-3 Bangi-dong Songpa-gu
Seoul, Korea (138-050)
http://www.unioncomm.co.kr
<Door Monitor>
0.None
1.Normal Open
2.Normal Close
[ESC][↑][↓][ENT]
Default setting: ‘0’
- ‘0.None’: In case door status is not checked
- ‘1.Normal Open’: In case of dead bolt type or automatic door
(In case lock monitoring is open when the door is locked)
- ‘2.Normal Close’: In case of strike type
(In case lock monitoring is close when the door is locked)
Select ‘0’ for no setting, ‘1’ for dead bolt type or automatic door and ‘2’ for strike
type. In case it is set to ‘1’ or ‘2’, information of the door connected to the
terminal is sent to the server periodically.
After selecting a setting value, press [ENT] button to continue setting.
3.5.3.3 Door Open Alarm Setting
Door Open Alarm
(00-30):00
[←] [↑] [↓] [→]
Default setting: ‘00’
The terminal checks how long the door is opened. This function issues an
alarm if the door is opened for a duration that exceeds the time in setting
(Min. 5seconds ~Max. 30 seconds).
If it is set to ‘00’, an alarm is issued. Even if it is set to 01~04, an alarm is
issued after at least 5 seconds are elapsed.
The door should be locked within the time in setting but the door may not be
locked due to unforeseen circumstances. In such a case, an alarm is issued to
determine the cause of a problem and take the necessary measures to ensure
normal door operation.
To use this function, the lock must have a monitoring function that checks the
opening/locking of the door. Also, the monitoring pin of the lock must be
connected to the terminal. In addition, the door open state check in the
previous item must be set to ‘1’ or ‘2’ in order to set this function.
After selecting a setting value, press down [F4] button for a longer period of
time to continue setting. Afterwards, all settings for the door are completed
and the system moves to the upper menu.